Vue de la page 0
Read these instructions carefully before installing, operating,
servicing or repairing this tool. Keep these instructions in a safe
accessible place.
Important
Operator Instructions
Includes - Foreseen Use, Work Stations, Putting Into Service, Operating,
Dismantling, Assembly and Safety Rules
Manufacturer/Supplier Product Type
Blows Per Min
Universal Air Tool Company Limited
Unit 8
Lane End Industrial Park
High Wycombe
Bucks
HP14 3BY
Tel No Fax No(01494) 883300 (01494) 883237
Model No/Nos Serial No
Product Nett Weight
lbs
Kg
Recommended Use Of
Balancer Or Support
Recommended Hose Bore
Size - Minimum
Recommended Max.
Hose Length
Ins M/M Ft M
Foreseen Use of the Tool
This tool is designed for the purposes of cleaning and restoring stone
and concrete, etc. and for cleaning and particularly removing paint and
rust, etc. from metals. The tool is powered by a free oscillating piston
which strikes a needle holder containing several hardened needles. The
needles have some free movement which allows the tool to clean
around irregular shaped surfaces.
Do not use the tool for any other purposes than that for which it was
designed. Do not modify the tool for any other purpose than that for
which it was designed even for its purposes as a needle scaler, unless
first agreeing any such alternative use or modifications, with the
manufacturer or an authorised representative. The main applications for
the tool is cleaning, deslagging and shot peening of welded joints,
cleaning metal surfaces of rust, scale and paint, cleaning castings,
removing cores, cleaning brick and stonework and cleaning ship
plates, barges and buoys.
Putting Into Service
Air Supply
Use a clean lubricated air supply that will give a measured air pressure
at the tool of 90 p.s.i./6.3 bar when the tool is running with the trigger
fully depressed. Use recommended hose size and length. It is
recommended that the tool is connected to the air supply as shown in
figure 1. Do not connect the tool to the air line system without
incorporating an easy to reach and operate air shut off valve. The air
supply should be lubricated. It is strongly recommended that an air filter,
regulator, lubricator (FRL) is used as shown in Figure 1 as this will supply
clean, lubricated air at the correct pressure to the tool. Details of such
equipment can be obtained from your supplier. If such equipment is not
used then the tool should be lubricated by shutting off the air supply to
the tool, depressurising the line by pressing the trigger on the tool.
Disconnect the air line and pour into the intake bushing a teaspoonful
(5ml) of a suitable pneumatic motor lubricating oil preferably
incorporating a rust inhibitor. Reconnect tool to air supply and run tool
slowly for a few seconds to allow air to circulate the oil. If tool is used
frequently lubricate on daily basis and if tool starts to slow or lose power.
Work Stations
The tool should only be used as a handheld,
hand operated tool. It is always recommended
that the tool is used when standing on a solid
floor. It can be used in other positions but
before any such use, the operator must be in a
secure position having a firm grip and footing
and be aware of a reaction force on the hand
as result of the tool doing work.
HP001T
4,300
3/8 10 30 10
No
3.5
1.6
Page No 1
Noise Level Sound Pressure Level 95.0 dB(A)
Test Method Tested in accordance with Pneurop
test code PN8NTC1
Vibration Level
Test Method Tested in accordance with ISO
standard 8662
13.8
Metres / Sec²
Air Pressure
Recommended Working
6.3
bar
90
PSI
Recommended Minimum
n/a
bar
n/a
PSI
Maximum
7.0
bar
100
PSI
Personal Safety Equipment
Use - Safety Glasses
Yes
Use - Safety Gloves
Yes
Use - Safety Boots
Use - Breathing Masks
Use - Ear Protectors
Yes
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Blows Per Min

Read these instructions carefully before installing, operating,servicing or repairing this tool. Keep these instructions in a safeaccessible place.Imp

Page 2 - Tool Maintenance

It is recommended that the air pressure at the tool whilst the tool isrunning is 90 p.s.i./6.3 bar. The tool can run at lower and higherpressures with

Page 3 - Apr 2012 Ver 1.00

HP001T Straight Needle ScalerPage No 3Apr 2012 Ver 1.00Ref No Part No Description1 HP001T-01 Air Inlet2 HP001T-02 Inlet Washer3 HP001T-03 Valve Bd

Page 4

DistributorNotesPage No 4This document may not be copied wholly or in part by anyone without the consent of the Directors of Universal Air Tool Compan